Polymeric Housed Metal Oxide Lightning Arrester / Surge Arrester

1 Set
MOQ
$58.00(1 - 4 Sets) $21.00(>=5 Sets)
Price
Polymeric Housed Metal Oxide Lightning Arrester / Surge Arrester
Features Gallery Product Description Request A Quote
Features
Specifications
Model Number: Y5W, Y5C, Y10W, Y10C
Basic Infomation
Model Number: Y5W, Y5C, Y10W, Y10C
Payment & Shipping Terms
Packaging Details: Wooden Case, Wooden Pallet, Carton, Gunny-bag
Product Description

Application
1. Arrester use under oil-immersed transformer.
2. GIS arrester
3. Railway arrester (DC substation yse,mount on rolling stock).
4. Polymeric protection arrester.
5. Cable sheath protection arrester.
6. Low voltage surge absorber.

Major Ratings

Application forl EC Standard Recom-mnded UR (kV rms) Model Dimensions(mm) Range of critical operating voltage V1mA-DC,kV-DC Max.residual voltage ration(VX kV/V1 mA)(at 8/20 μs) Current withstand capability
4/10ms(kv) 2ms(A)
Distribution 5kA 3.0 ZV0030-0020-32 21±1.0 4.55-5.40 1.78(at 5kV) 65 100
4.5 ZV0045-0030-32 31±1.0 6.80-8.10 1.78(at 5kV) 65 100
Distribution& Classl 10kA 3.0 ZV0030-0020-42 21±1.0 4.55-5.40 1.83(at 10kV) 100 400
4.5 ZV0045-0030-42 31±1.0 6.80-8.10 1.83(at 10kV) 100 400
Class 2 10kA 1.5 ZV0015-0012-52 12±1.0 2.10-2.40 1.79(at 10kV) 100 600
3.0 ZV0030-0023-52 24±1.0 4.18-4.82 1.79(at 10kV) 100 600
Class 3 10kA 1.5 ZV0015-0012-62 12±1.0 2.10-2.40 1.69(at 10kV) 100 1000
3.0 ZV0030-0023-62 24±1.0 4.18-4.82 1.69(at 10kV) 100 1000
Class 4 10kA 3.0 ZV0030-0023-75 24±1.0 4.18-4.82 1.78(at 20kV) 100 1300



Lightning arrester


Working Condition
1. Ambient air temperature:-40ºC~+60ºC;
2. Altitude:≤3000m;
3. Frequency 48Hz-62Hz;
4. Power frerequency voltage applied betweeen terminals of surge arrester must not exceed continuous operating voltage of surge arrester;
5. Earthquake(Seismic)intensity is less than 8 degree;
6. Max Wind speed is 35m/s;

Main Technicalparameter
Metal Oxide Varistor Polymer housed(Gapless)type Surge Arrester for A.C Systems(5kA,10kA,20kA)

Model Rated Voltage (kV ms) Continuous operating voltge (kV ms) Lightning Impulse Residual Voltage Under Nominal Discharge Current(≤vKp) Line discharge Class Creepage Distance(mm) 2ms square wave impulse current withstand(A) 4/10μ High Current impulse Withstand
YH/5/W-6 6 4.8 18 1 320 150 65
YH/5/W-9 9 7.2 27 1 430 150 65
YH/5/W-12 12 9.6 36 1 430 150 65
YH/5/W-15 15 12 45 1 530 150 65
YH/5/W-18 18 14.4 54 1 530 150 65
YH/5/W-21 21 16.8 63 1 640 150 65
YH/5/W-24 24 19.2 72 1 640 150 65
YH/5/W-27 27 21.6 81 1 740 150 65
YH/5/W-30 30 24 90 1 890 150 65
YH/5/W-33 33 26.4 99 1 890 150 65
YH/5/W-36 36 28.8 108 1 1115 150 65
YH/10/W-3 3 2.4 9 1 180 250 100
YH/10/W-6 6 4.8 18 1 240 250 100
YH/10/W-9 9 7.2 27 1 & 2 300/340 250 100
YH/10/W-12 12 9.6 36 1 & 2 380/400 250 100
YH/10/W-15 15 12 45 1 & 2 400/450 250 100
YH/10/W-18 18 14.4 54 1 & 2 510/400 250 100
YH/10/W-21 21 16.8 63 1 & 2 580/730 250 100
YH/10/W-24 24 19.2 72 1 & 2 640/730 250 100
YH/10/W-27 27 21.6 81 1 & 2 710/730 250 100
YH/10/W-30 30 24 90 1 & 2 780/1125 250 100
YH/10/W-33 33 26.4 99 1 & 2 840/1125 250 100
YH/10/W-36 36 28.8 108 1 & 2 920/1125 250 100
YH/10/W-42 42 33.6 126 2 & 3 1260 400 100
YH/10/W-45 45 36 128 2 & 3 1260 400 100
YH/10/W-54 54 42 160 2 & 3 1260 400 100
YH/10/W-60 60 48 178 2 & 3 1465 400 100

Performance Guarantee

Once u buy the product manufactured by Haibian Power Equipment (CHHP) can get 24 months performance guranantee after delivery date, or if there is any special reques, pls do not hesitate to contact us...

Thank you for visit.

Recommended Products
Get in touch with us
Contact Person : Terry
Characters Remaining(20/3000)